Optional remote reset – Magnum Venus Plastech CB-6000-RT - Resin Monitor User Manual

Page 27

background image

CB-6000-RT Material Monitor Manual

Rev. 10/2012

Page | 27

Optional Remote Reset:



Using the items listed below:

1 - 09125 Bulk head fitting
1 - 09449 Switch
1 - 09445 Operator
1 - 09068 Bracket
1 - 08801 Fitting
1’- 08810 1/8 Tubing (plus length to push button)
1 – 08802 Fitting
1 – 07223 Fitting
3’- 08247-BC Wire
1 – 09069 Push Button

Mount the switch (09449) in the desired location in the control box and connect the
operator (09445) to the switch (09449). Using wire (08247-BC), connect the switch to
terminals #7 and #10 on the back of the Resin meter. Mount the push button (09609) at
the remote location and connect with the tubing (08810), one end of the tubing to the air
supply and the other end to the operator (09445) on the switch (09449).

When you push the button an air signal is sent to the operator on the switch and the
circuit between terminals #7 and #10 is closed causing the resin meter to reset.