CB-6000-RT Material Monitor Manual
Rev. 10/2012
Page | 19
QUICK START:
Enter a number into the scale factor parameter (ASCFAC). Pump some material and
weigh the output then adjust the scale factor parameter accordingly to obtain the correct
total. Repeat this process until the unit displays the correct amount of material pumped,
the unit is now calibrated. Check that the following parameters and adjust the scale
factor accordingly:
(A C
n
t) cnt = one count per pulse (recommended), cnt 2 = two counts per pulse
(AdECPt) = 0.0 adjust the scale factor according to desired units (x10 – 0.0)
(ASCALr) = 1 multiplies scale by one (no change, recommended)
Periodically check the output weight to confirm the calibration and adjust accordingly.
The calibration should be automatically checked if a different resin is used or any
changes are made to the pumping system. The calibration process can be conducted
before the catalyst system is primed, that way the resin can be processed through the
gun for a more accurate calibration and the resin can be returned to the source without
fear of catalization. In this case the total weight will be off by the amount of catalyst used.
QUICK REFERENCE:
Enter a number and adjust accordingly
Use the to select the numeric column and the and to change its value.
Enter the desired Set Point number then press through the remaining parameters
unit the display reads
.
Note: Pressing the will exit the programming process without saving.