CB-6000-RT Material Monitor Manual

Rev. 10/2012

Page | 24

Resin Display Value = 60 for minutes multiplied by the decimal place x10 = 0.0

Minutes =

60

Decimal place:

x 10

Display Value (rdSP 1) 600 (pounds or kilogram per minute)


Resin Rate Input value:

Pounds

Kilogram

Pulses per pound

14

31

Decimal display

x 10

x 10

Input Value (r I

n

P 1) =

140

310

This number may need to be adjusted for the resin viscosity and specific gravity but it is
a starting point. Make note of all materials used (resin data sheet), pump settings,
nozzle size and nozzle type this will help to duplicate this setup in the future.

QUICK REFERENCE:







Use the to select the numeric column and the and to change its value.

Enter the desired Set Point number then press through the remaining parameters

unit the display reads

.


Note: Pressing the will exit the programming process without saving.







PAR

END

Pro

F1

4 - rtE

rdSP 1

PAR

RST

F1

F2

PAR

DSP

Push 3 times

600.0

RST

r I

n

P 1

PAR

580.0

RST