Introduction:


The Digital Monitor is designed to display the resin rate and resin total. By using a
sensor assembly, signals are sent to the control box from the resin pump. These
signals are then converted to produce the Resin Rate and Resin Total.

The Monitor is designed to be modular so that if one component becomes inoperative
the rest of the system will continue to operate and the inoperative component can easily
be replaced. It is easily configured for use on multiple pump systems.

After a simple calibration procedure the monitor will accurately display the Resin Rate
as well as the Resin Totals. After the system has been calibrated it only needs to be
checked periodically for quality control. The monitor may need to be fine tuned if a
different resin is used or if the pumping system becomes worn and less efficient.

CB-6000-RT-APS –
Includes the APS Resin sensor hardware kit – see CSD-1000-APS
CB-6000-RT-HV – Includes the HV Resin sensor hardware kit – see CSD-1000-HV
CB-6000-RGT-PAT – Includes the Patriot Resin sensor hardware kit – see PAT-SENS-100
CB-6000-RT-UPS – Includes the UPS Resin sensor hardware kit – see UPS-1000-UPS

Optional Valve Configuration:


The CB-6000-RT Monitor can be configured with a special valve to send an air signal.
This feature is helpful for use with the auto gun configurations. It can also be used to
limit the amount of material applied to a part for a hand held system. This signal can
be used to turn OFF a resin pump and chopper or ON/OFF some other device. After
counting up to a “Set Point” the number of counts on the resin total the unit will then
send a signal.

Note: a Triggering package may be required for use with the auto gun configurations, as
well as the valves to control the gun.

If your system includes the special valve package proceed to “Quick Start - Set Point:”
for the Digital Readout, otherwise proceed to “Calibration – Resin Total & Rate:”.