Meter Setup Sheets:

RESIN RATE METER SETUP SHEET:


4 – rtE Rate Input Parameters

Display

Description

Factory Setting

MVP Setting

rAtEE

n

Rate Assignment

rAtE – A

LO- Udt

Low Update Time

1.0

2.0

HI – Udt

High Update Time

2.0

4.0

rtE dP

Rate Decimal Point

0

0.00

rdSP 1

Display Value

1000

Enter value

r InP 1

Input Value

1000.0

Enter value