beautypg.com

Meter setup sheets – Magnum Venus Plastech CB-6000-GT Glass Monitor User Manual

Page 23

background image

CB-6000-GT Material Monitor Manual

Rev. 10/2012

Page | 23

Meter Setup Sheets:

GLASS TOTAL METER SETUP SHEET:

I – I

n

P Counter A Input Parameters


Display

Description

Factory Setting

MVP Setting

A Cnt

Operating Mode

cnt

ArESEt

Reset Action

2ErO

AdECPt

Decimal Position

0

0.0

ASCFAC

Scale Factor

1

Enter factor here

ASCALr

Scale Multiplier

1

ACNtLd

Count Load Factor

500

0

A P-UP

Reset Power-Up

no

yes


(All other parameters in I – I

n

P remain as set by the factory)

QUICK REFERENCE:





or


















PAR

Pro

F1

1 - I

n

P

PAR

F2