CB-6000-GT Material Monitor Manual
Rev. 10/2012
Page | 21
Glass Total Scale Factor (pounds) – (per strand of glass)
Display Decimal place
1
(1= 0 or 10 = 0.0 decimal display)
Pulses per pound –
ч
ч
ч
ч
1969
Scale Factor (ASCFAC) =
0.000507
Glass Total Scale Factor (kilograms) – (per strand of glass)
Display Decimal place
1
(1= 0 or 10 = 0.0 decimal display)
Pulses per Kilogram –
ч
ч
ч
ч
4355
Scale Factor (ASCFAC) =
0.00023
• GLASS RATE SCALING VALUES:
The glass rate is specified by two programmable parameters: A desired Rate Display
Value (rdSP 1) and a corresponding Rate Input Value (r I
n
P 1).
QUICK START:
Enter a value into the display value (rdSP 1) and Input value (r InP 1)
Display Value (rdSP 1) = 60 represents minutes
Input Value (r InP 1) = 1500 (any number as a starting point)
If the glass total meter is working run the chopper for one minute and the displayed rate
during that minute should be equal to the total amount of glass displayed after one
minute. The rate may jump up and down a little; this is due to the sampling rate and
pulses counted during that time.
The decimal place can be adjusted by multiplying the values by 10 or 100, both values
must be raised and lower by the same proportion i.e. if the display value is raised by a
multiple of 10 then the input value must be raised by the same. Both values must be
greater than 0.0.