The Glass Rate can be calculated by:
If the number of pulses per “single” unit (i.e. # of pulses per pound or kilogram) is
known, then it can be entered as the Scaling Input value and the Scaling Display value
will be entered as the following:
Display Value (rdSP 1) 1 = seconds, 60 = minutes and 3600 = Hours
Input Value (r I
n
P 1) = # of pulses per unit
Notes:
1.
The decimal place can be adjusted by multiplying the values by 10 or 100, both
values must be raised and lower by the same proportion i.e. if the display value is
raised by a multiple of 10 then the input value must be raised by the same.
2.
Both values must be greater than zero (0).
Glass Rate in Pounds –
Display Value (rdSP 1 = 60)
Input Value (r Inp 1 = 1969) per strand of glass
Glass Rate in Kilograms – Display Value (rdSP 1 = 60)
Input Value (r Inp 1 = 4355) per strand of glass
This number may need to be adjusted slightly up or down to more accurately reflect the
true output. Make several tests at different chopper speeds to help fine tune the accuracy.
Make note of all materials used and chopper settings this will help to duplicate this
setup in the future.
QUICK REFERENCE:
Use the to select the numeric column and the and to change its value.
Enter the desired Set Point number then press through the remaining parameters
unit the display reads
.
Note: Pressing the will exit the programming process without saving.