Install Valve onto Shift Block:

1. Install the nipple (PF-HN-06S-04) and reducer (PF-RA-04-02) onto the valve.

2. Install the mufflers (VPRO-2004) onto the valve.

3. Screw the two tube fittings (7701-6-4) into the valve body.

4. Hold the guard (VPRO-2002) and valve (VPRO-2003) up to the actuator body

(VPRO-2003) and attach with machine screws (F-MS-832-24).

5. Attach tube (MPM-2052-5.5) to the valve.

Remove Actuator Valve from Shift Block:

1. Remove the urethane tube (MPM-2052-5.5) from the valve body (VPRO-2003).

2. Unscrew the elbow (TRU-1021) from the end of the actuator (MPM-2598).

3. Remove the nut (MPM-2587) holding the actuator (MPM-2598) in place and pull the

actuator free.

4. Repeat the process for the other end if necessary.

Install Actuator Valve onto Shift Block:

1. Install the actuator (MPM-2598) into the actuator body (VPRO-2001) and install nut

(MPM-2587).

2. Thread the elbow (TRU-1021) into the end the actuator (MPM-2598).

3. Install the urethane tube (MPM-2052-5.5) onto the actuator (MPM-2598).

4. Install the urethane tube (MPM-2052-5) onto the elbow (TRU-1021).

5. Repeat process on the other end if necessary.