beautypg.com

Magnum Venus Plastech Pro Series 11:1 PRO PUMP VPRO-45110 User Manual

Page 14

background image

14

Turn Off Pressure:

1. Be sure all fluid pressure and air pressure is relieved from the Pro Pump assembly.

DANGER: To avoid serious injury or equipment damage, do not proceed unless the
system has been completely depressurized.



Remove Catalyst Pump:

1. Be sure the catalyst pump has been removed from the slave arms.


Remove Pro Pump:

1. Remove the air hose connected to the fitting (PF-HN-06S-04) on the Shift Block

assembly.

2. Remove the pick-up wand hose (VHSA-1000) from the elbow (PF-ME-12-12J) at the

bottom of the pump.

3. Remove the resin hose from the fitting (PF-ME-08-06) on the resin filter assembly

(FF-5000-100).

4. Remove the air supply from the tee (MPM-2584) on the shift block assembly.

5. Remove the two screws (7101-7-6) holding the pump to the pump mount.


Remove Foot Valve Assembly:

1. Mount the Pro pump in a vise.

CAUTION: Before proceeding, note the original position of the elbow (PF-ME-12-12J)
on the foot valve body (3101-19-1). When you reinstall the foot valve body, the elbow
must be oriented in the same position.

CAUTION: As you disassemble the equipment, lay out the components in the correct
order and direction. This will help you to reassemble them. Especially note the order
of the piston cup (3101-12-1), piston cup spacer (3101-13-1), and compression ring
(15936-1), and the directions they face. These directions are critical to proper
functioning of this equipment.

2. Use a wrench to remove the two hex cap screws (02681-38) which secure the

cylinder (15986-1) and foot valve body (3101-18-1) to the center section of the pump
(85729-3).

NOTE: Loosen the hex screws alternately to prevent distorting them.

3. Remove the foot valve body (3101-18-1) and the cylinder (15986-1) from the pump.