Magnum Venus Plastech Pro Series 11:1 PRO PUMP VPRO-45110 User Manual
Page 14

14
Turn Off Pressure:
1. Be sure all fluid pressure and air pressure is relieved from the Pro Pump assembly.
DANGER: To avoid serious injury or equipment damage, do not proceed unless the
system has been completely depressurized.
Remove Catalyst Pump:
1. Be sure the catalyst pump has been removed from the slave arms.
Remove Pro Pump:
1. Remove the air hose connected to the fitting (PF-HN-06S-04) on the Shift Block
assembly.
2. Remove the pick-up wand hose (VHSA-1000) from the elbow (PF-ME-12-12J) at the
bottom of the pump.
3. Remove the resin hose from the fitting (PF-ME-08-06) on the resin filter assembly
(FF-5000-100).
4. Remove the air supply from the tee (MPM-2584) on the shift block assembly.
5. Remove the two screws (7101-7-6) holding the pump to the pump mount.
Remove Foot Valve Assembly:
1. Mount the Pro pump in a vise.
CAUTION: Before proceeding, note the original position of the elbow (PF-ME-12-12J)
on the foot valve body (3101-19-1). When you reinstall the foot valve body, the elbow
must be oriented in the same position.
CAUTION: As you disassemble the equipment, lay out the components in the correct
order and direction. This will help you to reassemble them. Especially note the order
of the piston cup (3101-12-1), piston cup spacer (3101-13-1), and compression ring
(15936-1), and the directions they face. These directions are critical to proper
functioning of this equipment.
2. Use a wrench to remove the two hex cap screws (02681-38) which secure the
cylinder (15986-1) and foot valve body (3101-18-1) to the center section of the pump
(85729-3).
NOTE: Loosen the hex screws alternately to prevent distorting them.
3. Remove the foot valve body (3101-18-1) and the cylinder (15986-1) from the pump.