beautypg.com

Chapter 3-disassembly, Removal of plv-1000, Plv-1000 disassembly procedure – Magnum Venus Plastech PRESSURE LIMIT VALVE PLV-1000 User Manual

Page 18

background image


MAINTAINENCE AND REPAIR MANUAL

PLV-1000

MAGNUM VENUS PLASTECH

REV 1.00

APRIL 2010

PAGE 18

CHAPTER 3-Disassembly

REMOVAL OF PLV-1000

Caution: When removing PLV-1000, be sure to release fluid pressure from the system before

removing. System may be under pressure and could cause injury.

Set operating pressure at 0 psi.

Open recirculation valve and/or gun to purge pressure from fluid sections. Let drain until as much

fluid as possible has been purged.

Remove the pneumatic signal lines from the top of the PLV-1000 and remove the air fitting.

You can now remove the PLV-1000 from the unit and take it to a work area for maintenance.

PLV-1000 DISASSEMBLY PROCEDURE

Remove the Spring Housing from the Valve Body assembly. (Fig. 3.0)

FIG 3.0

Remove the Spring Retainer, Spring and O-ring from the Valve Body. (FIG 3.1)

FIG 3.1