beautypg.com

Magnum Venus Plastech ThermoJect V6SC User Manual

Page 9

background image

Patriot SSB Auto Instructions Issue 05 30/06//08

Page 9 of 17


5.2 Turn off machine air supply by pushing the emergency stop button to OFF locked
position.

6.0 Routine Maintenance


General.
Ensure working parts of machine are kept clean. Also ensure all controls and indicators
remain clean. The gauges are glass faced and can be cleaned with solvent however all other
plastic controls should be cleaned with non solvent based cleaners. Remove all spillages
from machine. Immediately correct any air leaks or seepage of any fluid from machine.

6.1 Resin pump. During normal use the resin pump lubrication cup needs to be topped up
with recommended pump lube fluid. This should be checked at least twice a week during
normal daily production use. See separate section 9.0 on internal part maintenance.


6.3 Optional Solvent Pump system. The Solvent tank requires no routine maintenance
however if dirt particles as sediment accumulate within solvent tank base remove and clean
and refill with fresh solvent.

The remaining solvent system should only be routinely maintained by weekly checks to
locate any leaks or damaged pipes which should be repaired immediately.

See separate sheet on internal part maintenance in section 12.0

7.0 Maintenance


Important Safety Note All maintenance work on the machine must be carried out with the
air supply to the machine disconnected and due caution must be observed when opening all
fluid and pneumatic connections by using personal protection against possible internal
residue pressures.

The following sections describe seal and internal fluid section maintenance procedures
accompanied by assembly and parts drawings.