Patriot SSB Auto Instructions Issue 05 30/06//08

Page 7 of 17

Proceed to extract a small quantity of heated resin at the test valve outlet. No more
than 150 cl is required . Stop the machine and remove the outer cover. Pour
sufficient heated resin carefully into the top of the pump gold block recess. Replace
machine cover and continue to recirculate.

Before any resin injection takes place observe the recirculation flow of resin back into
the holding tank to confirm no air is present in the flow at slow or higher speeds.








4.0 Machine Operation

4.1. Injection operation start and stop.

Recirculation.

It is recommended that when the machine is not injecting and especially prior to injection use
recirculation is switched on to keep all the fluid sections and resin at constant temperature. A
slow recirculation speed should be used meaning that the pump speed should be no more
than 0.5 to 1.0 l/min. (5-10 pump strokes per minute) To start recirculation press the
recirculation start button. To stop push the red stop button once.

Test sample

Note the PDC Counter can
only be adjusted when PDC
white button is continuously
pressed whilst pressing each
counter button to select
predetermined count number.

Note. If counter is set to zero
then it is NOT possible to press
green start

Counter reset

Count set


Note the PDC Counter may have 5 digits per count register.
Each digit represents nominal 100 cc resin displaced per
pump stroke.