Rod Guide and Cup Seal Installation – Adhesive unit:

1.

Install the Cup Seal (cup down) into the top of the Outlet Body. Take care that
the Cup Seal is all the way into the bottom of the seat area.


2.

Install the Rod Guide into the Outlet Body on top of the Cup Seal.
















3.

Screw the Packing Nut into the Outlet Body just to where it contacts the Rod
Guide


4.

Gently push the Piston Rod down through the Packing Nut, Rod Guide and Cup
Seal. Use caution not to damage the Cup Seal or Piston Rod.

5.

Firmly finish screwing the Packing Nut into the Outlet Body.










ROD SLEEVE

PISTON ROD

PACKING NUT

ROD GUIDE

CUP SEAL

OUTLET BODY