For systems with inlet Check Valve CV-2000 installed:

A. Remove the Check Valve (CV-2000) from the Inlet Body (4101-7-1).

B. Remove O-ring (O-S-013) and replace with new o-ring.

C. Remove the Inlet Tube Fitting from the check valve. Remove and discard the O-

Ring (O-S-013) replace with new o-ring depending on the inlet fitting.

D. Remove the Seat Housing (CV-2001) from the Spring Housing (CV-2002).

E. Remove and clean Spring (CV-2004) and Piston (CV-2003) with warm water.

F. Remove and clean O-ring O-S-011 with warm water, replace as necessary.

G. Clean Seat Housing and Spring Housing with warm water and inspect for

damage.

H. Install the Spring into Piston and Piston into the Spring Housing.

I. Install a new O-ring (O-S-011) into the Seat Housing and thread Seat Housing

onto Spring Housing.

J. Install the Tube Fitting into the outlet side of the Check Valve.

K. Install the rebuilt Check Valve (CV-2000) onto the Inlet Body.