Change of calibration engineering units – Liquid Controls IT200N User Manual
Page 7

Sponsler, Inc.
IT200N Remote Rate Indicator
pg. 7
DOC#: MN-200N-D.DOC
C.F. = Calibration Factor as entered in S1-S5 (S5 is the most significant digit)
EXAMPLE #2: F = 500 Hz C.F. = 250
Rate Displayed =
500 x 60
=
30,000
= 120
250
250
FIGURE 3
Change of Calibration Engineering Units
Assume that liters rather than gallons are the desired engineering unit.
Example # 3: K-Factor = 250 pulses per gallon
Liters = 3.785 per gallon
C.F. =
Pulses per Gallon
Units per Gallon
C.F. = 250/3.875
C.F. = 66 Pulses per liter
On the Factoring P.C.B.:
Set S1@6, S2@6, S3@0, S4@0, S5@0
Example #4: The Engineering Unit is pounds in 10
th
s CO
2
K-Factor = 250 pulses per gallon
Pounds of CO
2
= 8.470 per gallon
In order to establish 10
th
s, increase lbs./gal. by a factor of 10
C.F. = 250/84.7
C.F. = 3
Formula 3
- Gear Plate Selection Guide (24 pages)
- MS Meters (40 pages)
- MA4 Meter (32 pages)
- M-MA Meters (28 pages)
- HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion (8 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)