Card

Setup

Sealevel Systems COMM+4.PCI Page

6

Clock Modes

The COMM+4.PCI employs a unique clocking option that allows the end user
to select from divide by 4, and divide by 1 clocking modes. These modes are
selected at Header J1.

To select the Baud rates commonly associated with COM: ports (i.e. 2400,
4800, 9600, 19.2, … 115.2K bps) place the jumper in the divide by 4 mode
(silk-screen D4).

To select the Baud rates above 115.2K select the divide by 1 mode (silk-screen
D1).

Baud Rates and Divisors for the ‘DIV1’ mode

The following table shows some common data rates and the rates you should
choose to match them if using the adapter in the ‘DIV1’ mode.

For this Data Rate

Choose this Data Rate

1200 bps

300 bps

2400 bps

600 bps

4800 bps

1200 bps

9600 bps

2400 bps

19.2K bps

4800 bps

57.6 K bps

14.4K bps

115.2 K bps

28.8K bps

230.4K bps

57.6 K bps

460.8K bps

115.2 K bps


If your communications package allows the use of Baud rate divisors, choose the
appropriate divisor from the following table:

For this Data Rate

Choose this Divisor

1200 bps

384

2400 bps

192

4800 bps

96

9600 bps

48

19.2K bps

24

38.4K bps

12

57.6K bps

8

115.2K bps

4

230.4K bps

2

460.8K bps

1