Technical Description

The ACB-MP.PCI utilizes the Zilog 85230 Enhanced Serial Communications
Controller (ESCC). This chip features programmable baud rate, data format and
interrupt control. Refer to the ESCC Users Manual for details on programming the
85230 ESCC chip.


Internal Baud Rate Generator

The baud rate of the ESCC is programmed under software control. The standard
oscillator supplied with the board is 7.3728 MHz. However, other oscillator values
can be substituted to achieve different baud rates.


Control and Status Registers Definition

The control and status registers occupy 16 consecutive I/O locations. The following
tables provide a functional description of the bit positions. X = do not care.

Base Mode

D7

D6

D5

D4

D3

D2

D1

D0

+4

RD 0 IRQST 0

0

0 0 0 DSRA

+4

WR X X

X

0

X X X

X

+5

RD 485CLK

ECHOA

SYNCA_RTS

SYNCA_CTS

AM3 AM2 AM1

AM0

+5

WR 485CLK

ECHOA

SYNCA_RTS

SYNCA_CTS

AM3 AM2 AM1

AM0

+6

RD 0 0

0

0 RLA

LLA

TSETSLA

RXCOPTA

+6

WR X X

X

X RLA

LLA

TSETSLA

RXCOPTA

+14

RD SD7 SD6

SD5

SD4 SD3

SD2 SD1

SD0

+15

RD SD15 SD14 SD13

SD12 SD11

SD10 SD9

SD8

Field Description
IRQST

SCC interrupt status:

1 = No interrupt pending on ESCC

0 = Interrupt pending on ESCC.

DSRA

DSRA:

1 = DSRA not active

0 = DSRA active

LLA

Local Loopback:

1 = LL set

0 = LL not set

RLA

Remote Loopback:

1 = RL set

0 = RL not set

TSETSLA

TSET clock source:

1= Received TXC as source

0 = TRXCA as source

RXCOPTA

RXCOPTA:

1= Selects SCC PCLK for RTXCA

0 = Selects received RXC for
RTXCA

SYNCA_RTS

SYNCA _RTS:

1 = SYNCA connected to RTS

0 = SYNCA is high

SYNCA_CTS

SYNCA_CTS:

1 = SYNCA connected to CTS

0 = SYNCA is high

485CLK

TSET switches with TXD:

1 = clk switches

0 = no CLK switching

ECHOA

ECHO enable:

1 = echo disabled

0 = echo enabled

AM0 – AM3

I/O mode select. See table for valid interface options.

0 = High Impedance

SD0 – SD15

Optional security feature. Unique value per customer or application.

Default value = FFFF

Note: Default values are listed in bold

This manual is related to the following products: