Pwr-4505, Sensorlex, 8b isolated analog signal conditioning products – Impulse SCMXRAIL1 User Manual
Page 6: Features, Specifications
For information call 800-444-7644
38
SensorLex
8B Isolated Analog Signal Conditioning Products
8B
PWR-4505
25W Single Output Industrial DIN Rail Switching Power Supply
▲
Features
Universal AC Input (85-264VAC)
DC Compatible Input (120-370VDC)
Protections: Short Circuit, Over Load, Over
Voltage, Over Temperature
Mounts on DIN Rail TS-35/7.5 & 15
UL, TUV Approvals
CE Compliant, UL 508 Listed
Certified to EN60950-1
Compliant with EMC Directive EN50082-2
LED Indicator for Power On
Specifications
Input
85-264VAC, 120-370VDC
Frequency
47-63Hz
Input Current
1.5A/115VAC 0.75A/230VAC
Inrush Current
Cold start 30A/115VAC 60A/230VAC
Efficiency
72%
Output Voltage & Current Rating
5V, 5A
Temperature Coefficient
±0.03%/°C
Ripple Voltage
100mVp-p
Overload Protection
105-150% rated output power
Over Voltage Protection
5.75-6.75V
Over Temperature Protection
135°C detect on heatsink of power transistor
Dielectric Strength
Between input and output terminals: 3KV, 1 minute
Between input and FG: 1.5KV, 1 minute
Between output and FG: 0.5KV, 1 minute
Insulation Resistance
Between input and output terminals/input and FG/
Output and FG: 100M
Ω
/500VDC
Operating Temperature
-10°C to +50°C
Storage Temperature
-20°C to +85°C
Relative Humidity
10-95%
Mechanical Dimensions
3.66" x 3.07" x 2.24"
(l)(w)(h)
(93mm x 78mm x 57mm)
Terminal Screw
M3
Figure 9: PWR-4505 Physical Dimensions