METAL SURFACE HOUSING TO SINGLE GANG ELECTRICAL BOX
(Figure 11)
1. For exterior walls, apply 1/4 inch bead of silicone sealant
around rear perimeter surface of mounting bracket gasket.
Be sure there is sufficient sealant to make a good seal
between gasket and wall.
2. Use two 6-32 x 1 pan head screws provided to secure
mounting bracket and gasket to box.
3. Connect power and control lines to wire leads provided as
per the wiring instructions.
4. Plug connector into reader board.
5. Place
ENTRACOMP
®
26SA housing over mounting bracket.
Push housing in against wall. Secure housing to mounting
bracket in door opening using two 6-32 x 3/8 screws
provided. Secure housing to bracket at bottom using one
6-32 x 1/4 security screw provided or equivalent.
6. Place housing door into door opening and rotate key 90
degrees clockwise.
METAL SURFACE HOUSING WITHOUT ELECTRICAL BOX
(See Figure 12)
1. For exterior wall, apply sealant to rear perimeter of
mounting bracket gasket.
Secura Key • 25