Initial setup - cvx-1300 converter – Controlled Products Systems Group CVX-1300 User Manual
Page 3

Initial Setup - CVX-1300 Converter
The CVX-1300 will support many different input and output formats.
The CVX-1300 replaces the CVX-1200 and many of the standard Cypress CVT series of
converters (e.g. CVT-2232 CVT-9102).
A DIP switch determines which conversion process will be used.
A “Legacy” cross reference chart is provided to quickly determine which settings to use for standard
Cypress converter numbers. In most cases several baud rate options are available to expand the
capabilities of existing converters. The Legacy cross reference chart will list the converter CVT
number and the CVX numbers and the DIP switch setting that will apply. Use the converter
numbers to find the DIP switch settings on the CVX-1300 application charts.
Setting up the CVX-1300 converter:
1. First determine which converter (conversion process) is required for the application. This may be
one of the standard Cypress converters or one of the new converters that are now part of the
CVX-1300 library. All of the different conversion processes are described in detail in this manual.
Each process will have a wiring diagram and specification sheet to describe the wiring connections
and operation.
2. Set the DIP switch to the setting called out in the CVX application chart.
3. Refer to the wiring diagram for the particular converter that is being used. The wiring diagrams
are different depending upon the type of conversion being performed.
4. Connect power to the CVX-1300 board.
5. If the diagnostic indicator LED flashes Green slowly, a valid converter number has been selected.
If the diagnostic indicator is illuminated a solid Red color, an invalid DIP switch
setting has been made.
6. Connect peripheral devices (Readers, Panel, Switches etc.) according to the appropriate wiring
diagram.
LEGACY CONVERTER EXAMPLE: You need a CVT-2232 that operates at 2400 Baud.
The Legacy Compatibility chart calls out CVX numbers 1,2, and 3.
Looking at the CVX application charts for #1,#2,and #3 lists 3 baud rates.
Selecting the 2400 Baud rate for CVX converter #2 would yield a DIP switch setting of:
1 OFF, 2 ON , 3 OFF, 4 OFF, 5 OFF, 6 OFF, 7 OFF, 8 OFF
The wiring diagram would reference the Wiegand to Serial connections.
NOTE: The CVX-1300 does not use an onboard DB type connector for RS-232 serial signals.
Serial connections can be made directly to the 12 position connector.
An optional patch cord is available with a Female DB-9 connector and flying leads.
The wiring diagrams indicate the equivalent DB-9 connections to the CVX-1300 J3 connector.