beautypg.com

Wiring diagram #12 radionics to wiegand, Reader powered by external supply (8 to 16 vdc) – Controlled Products Systems Group CVX-1300 User Manual

Page 28

background image

Data 0
Data 1

Ground

Wiring Diagram #12 Radionics to Wiegand

Reader powered by external supply (8 to 16 VDC)

2.7 k Pullup Resistors
Must be installed as shown.
Resistor values between 1k and 10k
should work. Both resistors should be the
same value

Data Out (SIG)

DC

Power

Supply

(-)

(+)

Access
Control

Panel

Card

Reader

+VDC (+V)

Ground (-V)

Ground

+8 to +16 VDC In

Data Bender®

D0 Output
D1 Output

+5VDC

485(-)

485(+)