Mount receiver additional ultrarx receivers – Controlled Products Systems Group WKP5LM3 User Manual
Page 3
3
Mount Receiver
Additional UltraRX Receivers
NOTE: This step applies only if more than one
Receiver is being used.
Up to four Receivers can be used. Each Receiver will
need a different Identity. Set the Identity of the
Receivers by changing the Dipswitches as shown in
the chart below. The Default Identity is 1.
Receiver ID
Switch #2
Switch #3
1
OFF
OFF
2
ON
OFF
3
OFF
ON
4
ON
ON
Step 2: Connect power to Receiver (see
ULTRX900R manual).
Step 3: Within 15 seconds, enter the Master PIN
Number on the main Keypad:
The Keypad will beep twice and Receiver Relay will
buzz indicating programming is successful.
Repeat for additional Receivers.
Followed by Receiver Identity:
2
3
4
OR
OR
Step 1: On the Receiver, place Dipswitch #1 to the
ON position.
Step 2: Connect power to Receiver (see
ULTRX900R manual).
Step 3: Within 15 seconds, enter the Master PIN
Number on the main Keypad:
Then:
1
The Keypad will beep twice and Receiver Relay will
buzz to indicate programming is successful.
If and error tone is heard, the memory on the
Receiver will need to be cleared by holding down the
Learn button until LED starts to flash.
Set-Up with UltraRX Extreme
Range Receiver (ULTRX900R)
Step 1: Mount the Receiver
with the Terminal Block at the
bottom and the antenna
hanging straight down.
NOTE: Metal surfaces can
shorten the range of the
Receivers. If mounting on a
metal surface and long range is
required, use a non-metallic
spacer to move the Receiver
away from the metal surface.
Step 2: Connect the Relay Output of Receiver to the
gate or door. To connect to a Door Strike or Magnetic
Lock, see diagrams below.
1 2 3 4 5 6 7 8 9 10 11 12 13
1
3
2
4
5
6
7
8
9 10 11
+
-
N/O
COM
N/C
Door
Strike
Transformer/
Power Supply
Open/
Close
12 13
Door Strike- Normally Open (N/O) Connection
DC
AC
Optional external power
input 10-24 Vac or DC
1
3
2
4
5
6
7
8
9 10 11
+
-
Magnetic
Lock
Transformer/
Power Supply
12 13
Magnetic Lock- Normally Closed (N/C) Connection
DC
AC
Optional external power
input 10-24 Vac or DC
N/O
COM
N/C
Open/
Close
Proceed to Mount Keypad.
1 2
3
4
5
6
7
8
9
*
0
#
Cancel
Step 1: On the Receiver, place Dipswitch #1 to the
ON position.