Operation in an mcn network – CTI Products CCU-2 Channel Control Unit User Manual
Page 18
CCU-2 Hardware Reference
Troubleshooting
CTI Products, Inc.
68-11843-100
18
8.
Operation in an MCN Network
The CCU-2 module can operate in stand-alone mode with just connections to its
50 pin I/O connector and no connection to the MCN network. However, if it is
used in a system with one or more PCs running MCNRCD software it may be
monitored & controlled from those PCs.
A special set of Default files is available for use with MCN Config configuration
program for the CCU-2. Special items include:
Module Type:
CCU-2
Display Tables
CCU Input A, CCU Input B, CCU Output
The CCU Module configuration will include the following I/O points in the MCN
Config program:
I/O Point
Name
Display Table
1
Force A 1
CCU Input A
2
Force A 2
CCU Input A
3
Force A 3
CCU Input A
4
Force A 4
CCU Input A
5
Force A 5
CCU Input A
6
Force A 6
CCU Input A
7
Force B 1
CCU Input B
8
Force B 2
CCU Input B
9
Force B 3
CCU Input B
10
Force B 4
CCU Input B
11
Force B 5
CCU Input B
12
Force B 6
CCU Input B
13
Output 1
CCU Output
14
Output 2
CCU Output
15
Output 3
CCU Output
16
Output 4
CCU Output
17
Output 5
CCU Output
18
Output 6
CCU Output
19
Output 7
CCU Output
20
Output 8
CCU Output
The inputs will show the state of the external Force A and Force B inputs.
The output points will show the states of the 8 relays. (All relays should show
the same state).
The state of the latch may be changed by forcing one of the outputs on or off
as follows:
MCN State
CCU-2 Latch State
On
A
Off
B