IIB Hardware Reference

Option Switches

CTI Products, Inc.

68-10844-115

8

4.

Option Switches

Three sets of option switches are provided for module configuration. The module
must be power cycled or reset after these switches are set so that the options will
take effect. Table 2 describes the option switches and shows the factory defaults.

SWITCH

DESCRIPTION

DEFAULT

GROUP

unit address setting

refer to the MCN System Manual

00

MODULE

unit address setting

refer to the MCN System Manual

0

OPTION
position 1

receiver bank selector 1 (see Table 3)

DOWN

position 2

receiver bank selector 2 (see Table 3)

DOWN

position 3

receiver bank selector 3 (see Table 3)

DOWN

position 4

unit address selector

DOWN

Table 2 - IIB Option Switches

The Group and Module selector switches are used to set the unit address during
module installation.

The unit address selector switch (OPTION switch position 4) is only used at
installation time. Refer to section 6, Special Installation Instructions, for a
description of this switch. For normal operation, this switch must be in the
DOWN position.

An IIB can monitor 8 receivers when the Link Fail feature is disabled or 7
receivers when the Link Fail feature is enabled (one receiver bank). Option
switches 1 through 3 allow the IIB to monitor any receiver bank supported by the
Comparator I/O Module. The settings for these switches is shown in Table 3. If
the Link Fail feature is enabled, the last receiver on an IIB is unusable. The IIB
will not provide monitoring and control functions for that receiver.

Bank

Option Switch Position
1 2 3

Receiver
Numbers

0

DOWN DOWN DOWN

1 through 8

1

UP DOWN DOWN

9 through 16

2

DOWN UP DOWN

17 through 24

3

UP UP DOWN

25 through 32

4

DOWN DOWN UP

33 through 40

5

UP DOWN UP

41 through 48

6

DOWN UP UP

49 through 56

7

UP UP UP

57 through 64

Table 3 - Receiver Bank Selectors