IIB Hardware Reference
Option Switches
CTI Products, Inc.
68-10844-115
8
4.
Option Switches
Three sets of option switches are provided for module configuration. The module
must be power cycled or reset after these switches are set so that the options will
take effect. Table 2 describes the option switches and shows the factory defaults.
SWITCH
DESCRIPTION
DEFAULT
GROUP
unit address setting
refer to the MCN System Manual
00
MODULE
unit address setting
refer to the MCN System Manual
0
OPTION
position 1
receiver bank selector 1 (see Table 3)
DOWN
position 2
receiver bank selector 2 (see Table 3)
DOWN
position 3
receiver bank selector 3 (see Table 3)
DOWN
position 4
unit address selector
DOWN
Table 2 - IIB Option Switches
The Group and Module selector switches are used to set the unit address during
module installation.
The unit address selector switch (OPTION switch position 4) is only used at
installation time. Refer to section 6, Special Installation Instructions, for a
description of this switch. For normal operation, this switch must be in the
DOWN position.
An IIB can monitor 8 receivers when the Link Fail feature is disabled or 7
receivers when the Link Fail feature is enabled (one receiver bank). Option
switches 1 through 3 allow the IIB to monitor any receiver bank supported by the
Comparator I/O Module. The settings for these switches is shown in Table 3. If
the Link Fail feature is enabled, the last receiver on an IIB is unusable. The IIB
will not provide monitoring and control functions for that receiver.
Bank
Option Switch Position
1 2 3
Receiver
Numbers
0
DOWN DOWN DOWN
1 through 8
1
UP DOWN DOWN
9 through 16
2
DOWN UP DOWN
17 through 24
3
UP UP DOWN
25 through 32
4
DOWN DOWN UP
33 through 40
5
UP DOWN UP
41 through 48
6
DOWN UP UP
49 through 56
7
UP UP UP
57 through 64
Table 3 - Receiver Bank Selectors