11 specifications (cantilever transducer), Pecifications, Antilever – Cleveland Motion Controls ULTRA ISC CANTILEVER TRANSDUCER CLTSCM REV AA User Manual
Page 13: Ransducer, 11 s

MAN-70445-0
R
EV
AA
U
LTRA
S
ERIES
ISC
C
ANTILEVER
T
RANSDUCER
T
ECHNICAL
M
ANUAL
1.11 S
PECIFICATIONS
(C
ANTILEVER
T
RANSDUCER
)
Item:
Specification:
Transducer Weight
1T ALUM
1T STEEL
2T STEEL
1.9 lbs.
0.86 kg.
2.7 lb.
1.23 kg
3.7 lb.
1.68 kg
Weight + Mounting Kit
1T ALUM
1T STEEL
2T STEEL
Flange
2.9 lbs.
1.32 kg.
3.7 lbs.
1.68 kg
5.3 lbs.
2.41 kg
Bearing
2.3 lbs.
1.05 kg.
3.1 lbs.
1.41 kg.
4.2 lbs.
1.91 kg.
Pillow Block
4.8 lbs
2.18 kg.
5.6 lbs.
2.54 kg.
7.9 lbs.
3.59 kg.
Material
Strain Sensing beam - heat treated 4140 alloy steel
or 2024 T81 Aluminum
Body - 1117 Low Carbon steel
Finish Material
Corrosion resistant Zinc plated with clear Chromate
Gage Type
Semi-conductor strain gage, high gage factor (100 nominal)
Connector Type
M12 Quick-disconnect, 4 conductor, DC keyed
Excitation Voltage
Internally generated
Nominal Output Signal at Rated
MWF
Factory calibrated @ 0V= 0 Force; 10V=100% MWF
Non-destructive Overload
150% MWF
Ultimate Overload
300% MWF (typ) (500% for ratings > 25 lb-f
Maximum Voltage*, Base
(Ground)
50 Volts peak
Angular Deflection
0.01 inches Max. as measured at the far end of the sensing roll
with maximum load present. (Roll Journal deflection not included)
Operating Temperature Range
0 to 70 degrees C
32 to 158 degrees F
* 24V input circuit or +/- 10V output circuit
5