P S - 7 0 4 F O U R - C H A N N E L P O W E R S U P P L Y

2 - 5

MULTI-CHANNEL SYSTEM

In a multi-channel system where each channel is run on its own cable and
connected only to single-channel remote stations as in the following diagram,
there are no crosstalk issues because the channels do not share a common
ground. Consult the table “Belden Shielded Cables” in the next section for
cable recommendations.

Figure 2-3: Multi-channel System

In a multi-channel system where multiple channels are run from the PS-704 to
multiple channel stations as in the following diagram, crosstalk can be an
issue. This is because the channels will share a common ground at both ends
of the cable run. If this kind of connection will be used, refer to the section
“Crosstalk Considerations.”

Figure 2-4: Multi-channel to multi-channel

C hannel A

C hannel B

C hannel C

C hannel D

P S - 7 0 4

C hannel A

C hannel B

C hannel C

C hannel D

C hannel A

C hannel B

C hannel C

C hannel D

G nd

G nd

P S - 7 0 4

4 C hannel R emote S tation