1. Unpack the unit and inspect for any damage that may have occurred

during shipping.

2. Connect the proper AC mains cable.
3. Install the PS-704.
4. Connect the AC to the mains circuit. Connect the intercom lines and

program input as required.

5. Set the four termination switches on the rear panel to on.
6. Switch power on. The green power light should be on and the four red

short lights should be off.

7. Select program sends and set program levels as required using program

input level adjust and program send level. Program level controls on

unused channels should be set to the fully counterclockwise position.

8. Set levels and sidetone nulls at remote stations.
9. The intercom system should now be operating properly.
10. Read the rest of this manual for further information.

INSTALLATION

Choose the location of the PS-704. The unit requires access to AC power. It
should be located away from other equipment that generates excessive
amounts of heat. The choice of location will also depend upon the wiring
scheme (refer to the section “Wiring”).

INTERCOM LINE CONNECTION

The PS-704 provides two rear-panel 3-pin male XLR connectors for each
intercom line. These connectors are wired in parallel and intended for
loop-through connection. Any single-channel station or channel of a
multi-channel station connected on a line plugged into Channel A of the
PS-704 will be “party-lined” with all the other stations on that same channel.
In a multi-channel system, the goal is to assign specific people to the correct
group (i.e. the other people with whom they need to be in contact the most).
This is particularly important when the party line users are on a
single-channel beltpack or station; less so if they are on multi-channel
stations. The pinout of the intercom connectors is as follows:

Pin #1 --- Ground (shield)

Pin #2 --- Power

Pin #3 --- Audio