4. TROUBLESHOOTING GUIDE

A MULTIMETER WILL BE NEEDED

PROBLEM

SOLUTION

GATE WILL NOT RESPOND

WHEN GIVEN A COMMAND

1. CHECK POWER SUPPLY TO THE

CONTROL PANEL.

2. CHECK CONTROL PANEL FUSES.

3. CHECK HARD WIRE LINK FITTED

BETWEEN TERMINALS 1 & 2.

1.

CHECK SAFETY BEAMS ARE WIRED
CORRECTLY. (IF MORE THAN ONE
SET OF BEAMS ARE FITTED THEY
MUST BE WIRED IN SERIES.)

2. CHECK THAT THERE IS POWER

GOING TO THE BEAMS, IF NOT
RESTORE POWER.

3. IF SAFETY BEAMS ARE NOT FITTED

ENSURE THAT A HARD WIRE LINK IS
FITTED BETWEEN TERMINALS 2 & C1

4. REMOVE SAFETY BEAM WIRES 2 &

C1 FROM CONTROL PANEL AND
CHECK IF YOU HAVE A NORMALLY
CLOSED CIRCUIT COMING FROM
THE BEAMS.

1.

MOTOR WIRES ARE WRONG WAY
ROUND. CHECK AND PROVE MOTOR
DIRECTION BY MOMENTORIALLY
PULSING TERMINALS 2 & 3. THE
GATE SHOULD OPEN UP. TURN
AUTOMATIC CLOSING

OFF

(DIP

SWITCH 2) UNTIL MOTOR
DIRECTION HAS BEEN PROVED.

WHEN COMMISSIONING

GATE AUTOMATICALLY

OPENS BUT DOES NOT

AUTOMATICALLY CLOSE

GATES ARE OPEN BUT WILL

NOT CLOSE AND GREEN LED

IS FLASHING

CONTINUED ON NEXT PAGE