ZA4

2.6 - Wiring in the Safety Photocells

SAFETY BEAMS SHOULD BE FITTED APPROXIMATELY

15 INCHES FROM GROUND LEVEL

CONTROL PANEL

10 11 2 C1

C
NC

RX

10
11

TX

10
11

Fig 13

SAFETY

BEAM

RECEIVER

SAFETY

BEAM

TRANSMITTER

IF FITTING A SECOND ARC LINE SET OF SAFETY BEAMS THEN C & NC MUST BE WIRED IN “SERIES”

2.7 - Inserting the Radio Frequency Card

INSERT THE RADIO FREQUENCY
CARD INTO THE SMALL SOCKET
ON THE CONTROL PANEL
(ENSURE THAT THE POWER IS
TURNED OFF TO THE CONTROL
PANEL BEFORE INSERTING THE
FREQUENCY CARD)

ANTENNA

WIRING

POINT

Fig 14