PRe-INstALLAtIoN PRoceDURes

sanitizing Procedures

This

sanitizing procedure must be completed prior to installing the Max or Max Plus. The materials required

for the sanitizing procedure are listed below.
Materials Needed:

Phillips Screwdriver

Household Bleach (5.25% Sodium Hypochlorite)

¼” Food grade Polyethelyne Tubing, approx. 4 ft. length

A Pitcher

1. Unpack the

Max or Max Plus and check for damage.

2. Remove the top panel by removing the two Phillips head screws at

each rear corner. Pull up on the rear corners of the top panel and

set aside.

3. Pour 1.5 gallons of fresh filtered water into the cold tank.

4. Add ¼ cup of bleach to the full cold tank. Allow this water to remain

in the tank for 5-10 minutes.

5. Using pliers, remove the drain plug located on the right rear side of

the unit.

6. Catch the drain water in a pitcher or similar container and dispose

of it.

7. Rinse 3 gallons of fresh filtered water through the system.

Pre-Install Preparation – Filter configuration

1. Rinse the filters you are using with the

Max or Max Plus in your shop sink. Refer to 54753 Installation

Manual. Rinse at least 5 gallons of tap water through the filters.

2. Insert a 4-foot length of ¼” tubing into the rubber grommet on the back of the unit. This is your water feed

line for the unit. Push the tubing through the grommet until only approx. 1 foot of tubing remains on the

outside of the unit. See picture below.

3. Install a ¼” shut off on the end of the tubing that protrudes from the unit. Attach the other end of the shut

off to the water supply.

4. Open the filter compartment by grasping the filter access door on the right side and pulling it forward. See

picture below.

Labeled

“From

Filtration”

¼” Feed

Line Empty

(right port)

Leak

Detector

Labeled “To

Filters”

¼” New

Feed Line