Pre-installation procedures – Hydrotech PURA Max and Max Plus 15-LBGH2-PURA, 15-LBGH2-UV-PURA Operation Manual User Manual
Page 7

7
PRe-INstALLAtIoN PRoceDURes
sanitizing Procedures
This
sanitizing procedure must be completed prior to installing the Max or Max Plus. The materials required
for the sanitizing procedure are listed below.
Materials Needed:
Phillips Screwdriver
Household Bleach (5.25% Sodium Hypochlorite)
¼” Food grade Polyethelyne Tubing, approx. 4 ft. length
A Pitcher
1. Unpack the
Max or Max Plus and check for damage.
2. Remove the top panel by removing the two Phillips head screws at
each rear corner. Pull up on the rear corners of the top panel and
set aside.
3. Pour 1.5 gallons of fresh filtered water into the cold tank.
4. Add ¼ cup of bleach to the full cold tank. Allow this water to remain
in the tank for 5-10 minutes.
5. Using pliers, remove the drain plug located on the right rear side of
the unit.
6. Catch the drain water in a pitcher or similar container and dispose
of it.
7. Rinse 3 gallons of fresh filtered water through the system.
Pre-Install Preparation – Filter configuration
1. Rinse the filters you are using with the
Max or Max Plus in your shop sink. Refer to 54753 Installation
Manual. Rinse at least 5 gallons of tap water through the filters.
2. Insert a 4-foot length of ¼” tubing into the rubber grommet on the back of the unit. This is your water feed
line for the unit. Push the tubing through the grommet until only approx. 1 foot of tubing remains on the
outside of the unit. See picture below.
3. Install a ¼” shut off on the end of the tubing that protrudes from the unit. Attach the other end of the shut
off to the water supply.
4. Open the filter compartment by grasping the filter access door on the right side and pulling it forward. See
picture below.
Labeled
“From
Filtration”
¼” Feed
Line Empty
(right port)
Leak
Detector
Labeled “To
Filters”
¼” New
Feed Line
Drain Plug