sPecIFIcAtIoNs

Width/Depth/Height .................................................13” x 15” x 44” (33cm x 38cm x 112cm)

Water Connection ....................................................1/4 in. tubing

Cold Water Temperature .........................................41° - 43° F adjustable (5.0° C - 6.0° C)

Hot Water Temperature ..........................................175° - 180° F (79° - 82° C)

Recommended Service Pressure ...........................40-60 psi (275-414 kPa)

Max Service Pressure .............................................100 psi (862 kPa)

Rated Service Flow .................................................0.5 gpm (1.89 lpm)

Temperature ............................................................50-100 F (10-37 C)

Weight .....................................................................46 lb. (21 kg)

Electrical Supply ......................................................120V/60Hz

Control and Unit ......................................................0.7 amps

Heater ......................................................................4.0 amps

Total ........................................................................4.7 amps

eLectRIcAL UsAGe sPecIFIcAtIoNs

Model: 15-LBGH2-PURA (hot/cold), 15-LBGH2-UV (hot/cold with UV)

MoDeL DesIGNAtIoNs

Model

Description

tank capacity

15-LBGH2-PURA

Hot/Cold Max, Tower

3.5 liter cold

0.9 Gal

1.6 liter hot

0.4 Gal

15-LBGH2-UV-PURA

Hot/Cold Max Plus, Tower,

with UV

3.5 liter cold

0.9 Gal

1.6 liter hot

0.4 Gal

RePLAceMeNt coMPoNeNts

components

Part No.

Frequency of Replacement

1240 RO Pre-filter

41400076

12 months or as needed

1240 RO Post Filter

41400009

12 months or as needed

1240 RO Membrane

33001033

As Needed

QC10-SED1R

25568843

Every 500 gallons filtered (*every 5 months)

UV Lamp Housing Assembly,

Includes Housing and Quartz

Sleeve

89007

As Needed

Ballast and Starter Assembly

89010

As Needed

UV Lamp, 4-Watt, & Harness

89005

12 months or as needed

Circulating Pump, 120V

89009

As Needed

QC10-CBRR

15578543

Every 500 gallons filtered (*every 5 months)

* Based on 3 gallons of water consumption each day.

component Amp Draw

Heater

4.0

Compressor

0.7

Total

4.7