beautypg.com

Return to service – Hydrotech PURA Ultimate 19-GU-PURA Operation Manual User Manual

Page 18

background image

Return to Service

1. Slowly turn ON the water supply.
2. As the reservoir fills, depress and hold the Hot unlock button (left side of dual button) followed by the Hot

dispense button (right-most button) and verify that water dispenses from the faucet.

3. Depress and hold the Cold dispense button until water dispenses from the faucet.
4. Depress and hold the Room dispense button until water begins to flow.
5. Turn ON the Red Power Switch to start the chilling and heating processes.
6. Verify that the compressor and heater are both working. This is best accomplished by placing a hand on top

of the compressor to feel for vibration, and by dispensing water from the hot tank (after 5 minutes) noting a

temperature increase in the water.

7. Visually inspect water connections for any leaks.
8. Check that the UV lamp is functioning by observing a blue glow from the top of the UV cap.

9. Remove and clean the drip tray and grill. If the grill is damaged or heavily stained it should be replaced.
10. Wipe all surfaces around the drip tray and faucet nipple area with a bacterial cleaning wipe or spray.
11. Return the drip tray to the unit.
12. Clean the condenser grill.
13. Close the front and the top cover of the unit.
14. Taste the water. Check the unit is clean and functions to the customer’s satisfaction. If you are not satisfied

with the quality of the water, check the filters and flush additional water through the unit.

NOTE

Because it will take 3-5 hours for the RO system to fill the reservoir, take along a few jugs of

freshly prepared RO water from your shop to fill the reservoir for faster rinsing.

18

cAUTION!

do not remove the lamp from holder while illuminated and NEVER look

into a lit UV light.