Installation 7.3. start-up – Burkert Type 1058 User Manual
Page 9

9
Installation and Start-up
7.2. Installation
M4
M4
spring washer
Fix the fuse to the
clamping straps with
two cheese-head
screws (M4). This also
provides electrical
connection. The spring
washers prevent the
screws loosening.
→
Connect the power
→
Always connect protective conductor!
The connection cable is encapsulated with the coil AC19
and cannot be removed.
7.3. Start-Up
WARNING!
Danger due to improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar
with and completely understand the contents of the operating
instructions.
• In particular observe the safety instructions and intended use.
• The device/the equipment may be started by adequately trained
personnel only.
Before start-up, ensure that
→
the fuse has been fitted according to regulations,
→
the fuse is not damaged,
→
the connecting area is clean,
→
the connection has been properly made,
→
all screws are fully tightened.
english
PTB 01 ATEX 2064 U