Installation and Operation Manual

X-VA-1358-eng

Part Number: 541B041AAG

September, 2012

2-2

Section 2 Installation

Model 1358

2-3 Return Shipment

Prior to returning any instrument to the factory, contact your nearest Brooks
location for a Return Materials Authorization Number (RMA#). This can be
obtained from one of the following locations:

Brooks Instrument
407 W. Vine Street
P.O. Box 903
Hatfield, PA 19440 USA
Toll Free (888) 554 FLOW (3569)
Tel (215) 362 3700
Fax (215) 362 3745
E-mail: [email protected]
www.BrooksInstrument.com

Brooks Instrument

Brooks Instrument

Neonstraat 3

1-4-4 Kitasuna Koto-Ku

6718 WX Ede, Netherlands

Tokyo, 136-0073 Japan

P.O. Box 428

Tel +81 (0) 3 5633 7100

6710 BK Ede, Netherlands

Fax +81 (0) 3 5633 7101

Tel +31 (0) 318 549 300

Email: [email protected]

Fax +31 (0) 318 549 309
E-mail: [email protected]

Any instrument returned to Brooks requires completion of Form RPR003-1,
Brooks Instrument Decontamination Statement, as well as, a Material
Safety Data Sheet (MSDS) for the fluid(s) used in the instrument. This is
required before any Brooks Personnel can begin processing. Copies of the
form can be obtained from any Brooks Instrument location listed above.

2-4 Transit Precautions

To safeguard against damage during transit, transport the instrument to the
installation site in the same container used for transportation from the
factory if circumstances permit.

2-5 Installation

A. Location
For proper operation the Model 1358 must be mounted within 6 degrees of
true vertical. The inlet connection to the flowmeter is in the bottom end
fitting. The connections are normally horizontal female NPT. The use of a
level is recommended to assure vertical positioning. Piping must be
adequately supported to prevent undue strain on the flowmeter.

B. Piping Arrangement
It is recommended that bypass piping be installed around the flowmeter so
it may be isolated from the process line for servicing and cleaning. Refer to
Figure 2-1 for a typical installation.

CAUTION

!

Do not allow the float to fall out of the metering tube. A damaged Float
will affect the accuracy of the meter. Be careful not to break the tube
by pulling on it at an extreme angle or applying excessive force.