beautypg.com

8 troubleshooting – Nilfisk-ALTO Centix 40 User Manual

Page 27

background image

9

CENTIX 60

CENTIX 60 PREMIUM

english

1

2

3

4

Fault

Cause

Remedy

‡ Motor does not start.

> Fuse of the mains socket has

blown

• Reset the fuse

> Plug not inserted for opera-

tion on the central extraction
system/mobile operation

• Insert the plug into the clea-

ner socket. See sections 4.1.3
and 4.1.4

> Overload protection switch

has tripped

• Switch off the vacuum cleaner

and allow it to cool for approx.
5 minutes. If the cleaner can-
not be started again, contact
the Alto service department.

‡ Motor

runs

continuously

> Plugs for mobile operation

and for central extraction sys-
tem are both inserted

• Insert only one of the two

plugs into the cleaner socket

‡ Reduced suction power

> Clogged suction hose/nozzle

• Clean suction hose/nozzle

> Seal/tank rim between the up-

per section of the cleaner and
the dirt tank is dirty/defective

• Clean/replace seal

> Filter bag is full

• See section 7.2.2 „Replacing

filter bag“

> Filter element is clogged

• See section 7.2.3 „Replacing

filter bag“

-->

7.2.3 Replacing the filter

element

1. Remove the upper section of

the cleaner from the dirt tank
and deposit it with the filter
element facing upwards. Do
not place the upper section
of the cleaner on the guard
(1).

2. Turn the filter holder anticlo-

ckwise (2) and remove it (3).

3. Carefully remove the filter

element.

4. Clean the filter seal (4).

Check it for damage and
replace it if necessary.

5. Fit a new filter element.
6. Fit the filter holder and turn it

clockwise to secure it.

7. Dispose of the used filter

element in accordance with
legal regulations.

CAUTION:
Never use the vacuum cleaner
without a filter.

8 Troubleshooting