ELECTRICAL 

Step Five 

Strobe Alert Output (LC30 ‐ _ _ _ 2 Series):  With the 
Strobe Alert wired NC; it can be used as a high or low 
level  alarm,  depending  on  the  setting  for  the  invert 
switch.  The Strobe Alert can also be wired NO. 

 

Changing from 120 to 240 VAC:   
1. Remove  the  two  screws  from  the  top  of  the 

printed  circuit  board  (PCB)  and  gently  slide  the 
PCB  from  the  housing.    Use  caution  when 
removing the PCB.   

2. Located jumpers JWA, JWB and JWC on the PCB.   
3. To change to 240 VAC, remove jumpers from JWB 

and  JWC  and  place  a  single  jumper  across  JWA. 
To  change  to  120  VAC,  remove  jumper  JWA  and 
place jumpers across JWB and JWC. 

4. Gently  return  PCB  into  housing  and  replace  the 

two screws. 