SPECIFICATIONS/DIMENSIONS
Step Two
Controller
Supply voltage:
120 / 240 VAC, 50 ‐ 60 Hz.
Consumption:
5 Watts max.
Sensor inputs:
(1) flow switch
Sensor supply:
24 VDC @ 50 mA
LED indication:
Sensor, relay & power status
Contact type:
(1) SPDT Relay
Contact rating:
250 VAC, 16A
Contact output:
Selectable NO or NC
Contact delay:
0 to 60 seconds
Electronics temp.:
F: ‐40°to 158°
C: ‐40°to 70°
Enclosure rating:
NEMA 4X (IP65)
Enclosure material:
PP (U.L. 94 VO)
Enclosure mount.:
3/4” NPT (Rc)
Enclosure rotation:
300°swivel base
Conduit entrance:
Single, 1/2" NPT
Classification:
General purpose
Certificate number:
LR 79326‐3
CE compliance:
EN 61326 EMC
EN 61010‐1 Safety
Strobe Alert
Flash type:
Xenon tube
Flash frequency:
1 per second
Strobe life:
10M cycles
Supply voltage:
120 VAC, 50‐60 Hz.
Consumption:
3 Watts max.
Material:
Polycarbonate
Enclosure rating:
NEMA 4X (IP65)
Color:
Amber
Terminal Labels:
(S) terminal:
Provides 14 VDC to the switch input
(‐) terminal:
Ground
(+) terminal:
Provides 24 VDC power to the switch
Side View
(LC30‐1001 & LC30‐1051)
Side View with Strobe Alert
(LC30‐1002 & LC30‐1052)
LC30 Series
Functional Diagram