beautypg.com

Datamax-O'Neil I-Class Peel and Present Option User Manual

Page 8

background image

6

Periodic

Maintenance


The Peel Mechanism Rollers will need to be disassembled and cleaned approximately every 100,000
inches to ensure trouble free operation. This cleaning interval may be more or less depending on the type
of adhesive on the back of your media. Heavy or “gummy” adhesive will require more frequent cleaning.

Upper Rollers:


 Remove the Peel Mechanism from the printer.

Press in on the Latch and allow the Front Cover
to swing open.


 Remove the small C-Clip from the Upper

Roller Shaft.



C-Clip

Latch

Front

Cover

Upper Roller

Shaft




 Remove Upper Roller Shaft and associated

Rollers. Note the order of the Rollers as they
are removed, they must be re-installed in the
same order.


 Clean

all surfaces of the Rollers and the Upper

Roller Shaft. Isopropyl Alcohol can be used,
for heavy or stubborn deposits WD-40

or an

adhesive remover can be used. Be sure all the
ridges on the rollers are free of debris.


 Re-assemble the Upper Roller Shaft, Rollers,

and C-Clip into the Peel Mechanism Assembly.

Upper Roller

Shaft

Rollers