beautypg.com

Firmware required, Preparing the printer – Datamax-O'Neil I-Class RFID HF & UHF Option User Manual

Page 3

background image

1

CAUTION

This device complies with FCC Radio Frequency exposure limits for an
uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 20cm between the radiator and your body. If 20cm distance
cannot be maintained, end users are to be 20cm from printer extremity.

Any changes or modifications to this RFID module not expressly approved by
Datamax-O’Neil Corporation will void the user’s authority to operate the
equipment.

Operation is subject to the following conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of this device.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

to part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at their own expense.



Firmware

Required

This option requires Application Version 10.065 (or greater).


Preparing the Printer


Start this installation by ensuring that the correct Application Version is resident:

1. With media loaded and the printer powered ON, press the

Key.

Note: Use 2-inch (51 mm) or wider media with a Label Width setting that is matched to the label’s width;

see the Operator’s Manual for details.



2. Using

the

Key, scroll to PRINT CONFIGURATION.



3. Press

the

Key.



4. Examine the label for the Application

Version. Ensure that the Application
Version is 10.065, or greater.

5. If necessary, download the file ftp://ftp.datamax-oneil.com then follow the “Updating Printer

Firmware” procedure in the Operator’s Manual.

SYSTEM SETTINGS

INTERNAL MODULE

1024

SCALABEL FONT CACHE

232

SYMBOL SET

DATAMAX

ABSOLUTE COUNTERS

0 inches
DATE NOT SET

RESETTABLE COUNTERS

CONFIGURATION

DATE NOT SET

PRINTER KEY:

4208-PA99-000412-488

APPLICATION VERSION:

83-2368-07ZN1 07.26 CP 09/19/2003

BOOT LOADER:

83-2268-02M 03.04 10/31/2000