Maintaining the Peel & Present Assembly
To ensure trouble free operation, the Peel & Present Assembly should be cleaned after every 100,000
inches (254,000 cm) of media use. This interval depends on the label adhesive, where “gummy”
adhesives may require more frequent cleaning. (To easily track label usage, go to SYSTEM SETTINGS
MEDIA COUNTERS in the printer’s menu system.) Clean the assembly as follows:
1. Turn ‘Off’ the Power Switch and unplug the power cord from the AC Receptacle. Raise the Access
Cover and remove the media from the printer.
2. Remove the Peel & Present Assembly from the printer.
3. Using compressed air or a soft brush, clean the Sensors.
Note: For cleaning heavy deposits, isopropyl alcohol can be used – provided it is carefully
applied using a cotton swab, and then allowed to dry before reconnecting the option to the
printer.
Cotton
Swab
Sensors
Peel Edge
Peel & Present
Assembly
4. Using a Cotton Swab dampened with isopropyl alcohol, wipe the Peel Edge clean.
5. Reinstall the Peel & Present Assembly onto the printer.
6. Reload media, and close the Access Cover to complete the procedure.