beautypg.com

Datamax-O'Neil H-Class Present Sensor Option User Manual

Page 5

background image

3

Step 3: Using the Option

During operation, labels will be dispensed “on-demand” – that is, subsequent printing will occur only after a

previously printed label has been removed from the printer. As a reminder, “REMOVE LABEL” will be

displayed to prompt you when a label awaits removal. Begin using the option as follows:

A) Load media and close the Access Cover (see the Operator’s Manual for details).

B) Plug the power cord into the AC Receptacle and turn ‘On’ the Power Switch.

C) Ensure that READY is displayed on the Front Panel then press the FEED Key, and proceed

according to your observations:

If REMOVE LABEL is displayed on the Front Panel, this completes the installation; or,

If REMOVE LABEL is not displayed on the Front Panel, proceed to Step 4: “Configuring the

Printer.”

FEED

Key

Front Panel

Notes: (1) The operation of the Present Sensor can also be controlled by host software commands,

so ensure that your labeling program is properly configured for use when sending label

formats to the printer.

(2) If the Present Sensor is removed with power applied, the printer will behave as if a label

awaits removal; to restore normal operation, cycle power to the printer.