Datamax-O'Neil H-Class RFID Option User Manual
Page 7
5
•
Quick RFID Calibration –
With the printer at READY, simultaneously press FEED
and TEST;
WED 09:32A 24MAR2006
READY
PAUSE
CANCEL
FEED
CONFIGURATION
FEED Key
&
TEST Button
RFID
– or –
•
Standard RFID Calibration –
1) From the ADVANCED MENU, press MENU.
2) Using the UP or DOWN Button, scroll to PRINTER
OPTIONS and press ENTER.
3) Scroll to RFID and press ENTER.
4) Scroll to PERFORM CALIBRATION and press ENTER.
WED 09:32A 14MAR 2006
OFFLINE
RFID
EXIT
ENTER
SYSTEM
RFID MODULE
RFID POSITION
HF SETTINGS
UHF SETTINGS
LOCK AFTER WRITE
RETRY ATTEMPTS
RFID
PERFORM CALIBRATION
SET DEFAULTS
ENTER Key
UP & DOWN
Buttons
Using either method, you will be prompted to PERFORM CALIBRATION? Answering YES at the prompt
will initiate the process (while NO will terminate it). If yes, the CALIBRATING RFID message will appear
and the printer will begin scanning the media for the RFID tag location. Once located, power calibration
occurs. Wait briefly while both processes finish.
Upon completion the media is retracted to the TOF position; a brief outcome message is displayed; and,
the database is updated with the new parameters.
Note: If using the Standard RFID Calibration method, an additional pop-up window allows detailed
calibration results to be viewed and printed (see below).