Quick RFID Calibration –

With the printer at READY, simultaneously press FEED

and TEST;



WED 09:32A 24MAR2006

READY

PAUSE

CANCEL

FEED

CONFIGURATION

FEED Key

&

TEST Button

RFID

– or –


Standard RFID Calibration –

1) From the ADVANCED MENU, press MENU.

2) Using the UP or DOWN Button, scroll to PRINTER

OPTIONS and press ENTER.

3) Scroll to RFID and press ENTER.

4) Scroll to PERFORM CALIBRATION and press ENTER.




WED 09:32A 14MAR 2006

OFFLINE

RFID

EXIT

ENTER

SYSTEM

RFID MODULE
RFID POSITION
HF SETTINGS
UHF SETTINGS
LOCK AFTER WRITE
RETRY ATTEMPTS

RFID

PERFORM CALIBRATION

SET DEFAULTS

ENTER Key

UP & DOWN

Buttons

Using either method, you will be prompted to PERFORM CALIBRATION? Answering YES at the prompt

will initiate the process (while NO will terminate it). If yes, the CALIBRATING RFID message will appear

and the printer will begin scanning the media for the RFID tag location. Once located, power calibration

occurs. Wait briefly while both processes finish.


Upon completion the media is retracted to the TOF position; a brief outcome message is displayed; and,

the database is updated with the new parameters.

Note: If using the Standard RFID Calibration method, an additional pop-up window allows detailed

calibration results to be viewed and printed (see below).