Step 2: know the printer, The factory default setting to be modified – Datamax-O'Neil H-Class RFID Option User Manual
Page 5
3
Step 2: Know the Printer
For easy setup and configuration, most RFID settings can be modified via the Control Panel. Depending
upon your RFID hardware option, the factory default settings are as follows:
HF RFID Default Settings (RFID MODE = HF):
RFID POSITION = 1.10
HF SETTINGS:
TAG TYPE = ISO 15693
RETRY ATTEMPTS = 3
UHF RFID Default Settings (RFID MODE =
UHF):
RFID POSITION = 1.10
UHF SETTINGS:
TAG TYPE = GEN 2
TAG DATA SIZE = 96-BIT
RETRY ATTEMPTS = 3
WED 09:32A 14MAR 2006
OFFLINE
PRINTER OPTIONS
EXIT
ENTER
SYSTEM
MODULES
PRESENT SENSOR
CUTTER
SCANNER
RFID
GPIO PORT
REWINDER
RFID
RFID
UP & DOWN
Buttons
ENTER Key
EXIT Key
MENU Button
To change a factory default setting using the Control Panel, begin by accessing the ADVANCED MENU:
1) Press MENU.
2) Using the UP or the DOWN Buttons, scroll to SYSTEM SETTINGS then press ENTER.
3) Scroll to MENU MODE then press ENTER.
4) Scroll to ADVANCED MENU then press ENTER.
Next, select the factory default setting to be modified (for example, RETRY ATTEMPTS):
1) Press MENU.
2) Scroll to PRINTER OPTIONS then press ENTER.
3) Scroll to RFID then press ENTER.
4) Scroll to
the factory default setting to be modified
then press ENTER.
5) Enter the desired setting or parameter then press ENTER.
6) Press EXIT; and, at the SAVE CHANGES prompt, press YES.
Notes: (1) If NOT INSTALLED is displayed after selecting RFID, then the device is not equipped or
is not communicating. In this case, proceed to the MODE setting and ensure that the correct
RFID device has been selected.
(2) For User Interface details, see the Operator’s Manual.
(3) To restore factory defaults, select SET DEFAULTS in the RFID options menu.