beautypg.com

Datamax-O'Neil ANDES 3 User Guide User Manual

Page 15

background image

11

3.2.2 Setting Dip Switches

ON

1

2 3 4 5

6 7

8

FIGURE 12: EXAMPLE: DIP SWITCH #1 SHOWN IN ‘ON’ POSITION

Note: Use care when changing dip switch settings. Carefully use a pointer on the dip switch
you are going to change. DO NOT use a screw driver or apply excessive force.

3.2.3 Dip Switch Functions

Note: (Developer’s refer to Programming Manual for more information)

Table 2 – DIP Switch Setting

Dip Switch

Function

Switch #

Switch #

Switch #

Notes

1 & 2

Communication Interface

SW 1

SW 2

RS232

OFF

OFF

Baud rate set by Dip switches 3,4 and 5

IrDA

ON

OFF

Baud Rate can be negotiated up to the value
specified through Dip switches 3,4 and 5

Bluetooth

OFF

ON

BT Baud Rate set for 57600 bps.
Dip switches 3,4 and 5 must be set to OFF
position

802.11b

ON

ON

802.11 Baud Rate set for 57600 bps
Dip switches 3,4 and 5 must be set to OFF
position

3 & 4 & 5

Baud Rate

SW 3

SW 4

SW 5

57600

OFF

OFF

OFF

38400

OFF

ON

OFF

19200

ON

ON

OFF

14400

OFF

OFF

ON

9600

ON

OFF

ON

Use for fixed IrDA

2400

OFF

ON

ON

1200

ON

ON

ON

6

Parity Bit

SW 6

Parity Enabled

ON

Does not apply for IrDA

Parity Disabled

OFF

Does not apply for IrDA

7

Odd/Even

SW 7

Even Parity Checker

ON

Does not apply for IrDA

Odd Parity Checker

OFF

Does not apply for IrDA

8

Auto Power Save

SW 8

Power Save Disabled

OFF

Manual On/Off

Power Save Enabled

ON

Auto Power Down

Note: In order for changes to the dip switch configuration to take effect, the printer power
must be reset. This action occurs automatically when the battery is removed to gain access