beautypg.com

ALLIED Vision Technologies Manta G-917 User Manual

Page 114

background image

Manta Technical Manual V7.0.1

114

Camera interfaces

Signal

Description

GPO

Configured to be a general purpose output, control of which is assigned to
SyncOutGpoLevels

AcquisitionTriggerReady Active once the camera has been recognized by the host PC and is ready to start

acquisition

FrameTriggerReady

Active when the camera is in a state that will accept the next frame trigger

FrameTrigger

Active when an image has been initiated to start. This is a logic trigger internal
to the camera, which is initiated by an external trigger or software trigger
event

Exposing

Active for the duration of sensor exposure

FrameReadout

Active at during frame readout, i.e. the transferring of image data from the
CCD to camera memory

Imaging

High when the camera image sensor is either exposing and/or reading out
data

Acquiring

Active during an acquisition stream

SyncIn1

Active when there is an external trigger at SyncIn1

SyncIn2

Active when there is an external trigger at SyncIn2

Strobe1

The output signal is controlled according to Strobe1 settings

Table 39: Output signals

Figure 74: Output block diagram

GPO

Output signal

Optocoupler

Polarity

selectable

via software

Read from

software

Output

mode

selectable

via software

AcquisitionTriggerReady

FrameTriggerReady

FrameTrigger

Exposing

FrameReadout

Acquiring

SyncIn1
SyncIn2

Strobe1