beautypg.com

Mediashield™ controller – Asus M2NPV-VM User Manual

Page 37

background image

A S U S M 2 N P V - V M

A S U S M 2 N P V - V M

A S U S M 2 N P V - V M

A S U S M 2 N P V - V M

A S U S M 2 N P V - V M

1 - 2 7

1 - 2 7

1 - 2 7

1 - 2 7

1 - 2 7

4 .

4 .

4 .

4 .

4 .

S e r i a l A T A c o n n e c t o r s

S e r i a l A T A c o n n e c t o r s

S e r i a l A T A c o n n e c t o r s

S e r i a l A T A c o n n e c t o r s

S e r i a l A T A c o n n e c t o r s
( 7 - p i n S A T A 1 , S A T A 2 , S A T A 3 , S A T A 4 )

( 7 - p i n S A T A 1 , S A T A 2 , S A T A 3 , S A T A 4 )

( 7 - p i n S A T A 1 , S A T A 2 , S A T A 3 , S A T A 4 )

( 7 - p i n S A T A 1 , S A T A 2 , S A T A 3 , S A T A 4 )

( 7 - p i n S A T A 1 , S A T A 2 , S A T A 3 , S A T A 4 )
These connectors are for the Serial ATA signal cables for Serial ATA
3.0 Gb/s hard disk and optical disk drives. The Serial ATA 3 Gb/s is
backward compatible with Serial ATA 1.5Gb/s specification.

The current Serial ATA I interface allows up to 150 MB/s data transfer
rate while Serial ATA II allows up to 300 MB/s data transfer rate,
faster than the standard parallel ATA with 133 MB/s (Ultra DMA133).

If you install Serial ATA hard disk drives, you can create a RAID 0,
RAID 1, RAID 0+1, RAID 5, and JBOD configuration through the
onboard NVIDIA

®

MediaShield™ controller.

M2NPV-VM

®

M2NPV-VM SATA connectors

GND

RSATA_TXP1
RSATA_TXN1

GND

RSATA_RXP1
RSATA_RXN1

GND

SATA1

GND

RSATA_TXP2
RSATA_TXN2

GND

RSATA_RXP2
RSATA_RXN2

GND

SATA2

GND

RSATA_TXP4
RSATA_TXN4

GND

RSATA_RXP4
RSATA_RXN4

GND

SATA4

GND

RSATA_TXP3
RSATA_TXN3

GND

RSATA_RXP3
RSATA_RXN3

GND

SATA3

I m p o r t a n t n o t e o n S e r i a l A T A

I m p o r t a n t n o t e o n S e r i a l A T A

I m p o r t a n t n o t e o n S e r i a l A T A

I m p o r t a n t n o t e o n S e r i a l A T A

I m p o r t a n t n o t e o n S e r i a l A T A

Install the Windows

®

2000 Service Pack 4 or the Windows

®

XP Service

Pack1 before using Serial ATA.

For detailed instructions on how to configure RAID 0, 1, 0+1, 5,and
JBOD, refer to the RAID manual in the support CD.

The RAID function of these connectors is set to [Disabled] by
default. If you intend to create a Serial ATA RAID set using these
connectors, enable the R A I D E n a b l e d

R A I D E n a b l e d

R A I D E n a b l e d

R A I D E n a b l e d

R A I D E n a b l e d item in the NVRAID

Configuration sub-menu in the BIOS. See section “2.4.6 Onboard
Device Configuration” for details.