5.5.3 - Unbalance optimization

The symbol

is displayed automatically for static unbalance exceeding 30 grams (1.1 oz). The program allows

reducing the total unbalance of the wheel by compensating, when possible, the unbalance of the tyre with that of the
rim. It requires two spins with rotation of the tyre on the rim in the second spin.

Press

+

after a first spin and follow the instructions appearing on the monitor.

5.5.4 - Correction mode

After having performed automatic measurement of the inner side, it is possible to place the correction weights as

required by pressing pushbuttons

and

.

N.B.: In the event of automatic measurement of both sides, if the difference between the inner and

outer diameters is greater than or equal to 2”, the system sets the inner side spring weight. To

modify this presetting, press the

button. The external side may only be “adhesive”.

To display static unbalance, press the

button on the measurement screen (for ALUS static, the inner side

diameter is always considered).

UNBALANCE OPTIMIZATION

Make sure that the previous spin was made with the wheel now fitted on the wheel

balancer.

Trace the rim adaptor position with a reference mark to allow re-assembling on the

adaptor in the same position.

Remove the wheel from the balancer.

Turn the tyre 180° on the rim.

Re-assemble the wheel on the balancer by positioning the rim reference mark with

the adaptor’s.
Close the wheel guard and push (START)

Abort

Load

Save