background image

I 0463 - 13

8

8a

Pos B

Pos A

FI

GB

5.3 - Presetting of wheel dimensions

5.3.1 - Automatic presetting (see also

CORRECTION MODE

)

5.3.1.1 - Standard wheels

The screen appears upon removing the distance + diameter gauge.
The “dimension acquired” message is indicated by the correction weight symbol, which changes from blue to red.
- INNER SIDE WEIGHT: Using the special grip, move the end of the gauge against the rim in position:
a)

Sprung weight : in one of the positions A/B indicated in figure 8.

INDICATOR

L.T. function enabled

(see Buttons

Enabled)

INDICATOR: Width

Sonar function

enabled

b)

Adhesive weight: in the position indicated below

Note: Always use the round part of the striker plate.
- Hold the gauge in position for at least 2 seconds.
If the acoustic signal is enabled (see

ACOUSTIC SIGNAL

), the acquisition of the dimensions is accompanied by a

“beep”.

Position of adhesive

weight

Load

Save

Manual