I 0322 - 14
I 0322 - 15
/
/
10
GB
GB
5.3.1.3 - WHEELS ALU-S
After the measurement performed for the FI inner side, as indicated in fig. 8/9, pull out the gauge again to
store the data for the FE outer side; choose position A or B (fig. 8) at your choice. Keep this position for at
least 2 seconds. The counterweight symbols change colour.
When the acoustic signal is enabled (see
ACOUSTIC SIGNAL
), the acquisition is accompanied by a “beep”.
After having detected the dimensions, use the
key to indicate the type of correction selected for the
inner side.
The following buttons are enabled:
Management of save user recall
Selection of clip or adhesive weight for inside.
Only for automatic width option:
The
L.T. key (LIGHT TRUCK) used to improve the dimensional calibration of large-diameter wheels
such as off-road, trucks, wheels which protrude significantly from the rim. Press the
L.T. key, after
distance measurement, immediately before lowering the guard for Width Measurement.
The option is disengaged at the end of current Width Measurement.
Selecting the manual dimension presetting screen
Return to initial screen
Balancing run
Position of
adhesive
weights